73 research outputs found

    Near-infrared spectroscopy as a tool for marine mammal research and care

    Get PDF
    This project was partially funded by the Department for Business, Energy and Industrial Strategy Offshore Energy Strategic Environmental Assessment Programme. Supplementary funding supporting JM was provided by the US Office of Naval Research (ONR) grant nos. N00014-18-1-2062 and N00014-20-1-2709. Supplementary funding supporting AF and JM was provided by the US Office of Naval Research (ONR) grant no. N00014-19-1-2560. Supplementary funding supporting BS-C, JK, and AR was provided by the US Office of Naval Research (ONR) grant no. N00014-19-1-1223.Developments in wearable human medical and sports health trackers has offered new solutions to challenges encountered by eco-physiologists attempting to measure physiological attributes in freely moving animals. Near-infrared spectroscopy (NIRS) is one such solution that has potential as a powerful physio-logging tool to assess physiology in freely moving animals. NIRS is a non-invasive optics-based technology, that uses non-ionizing radiation to illuminate biological tissue and measures changes in oxygenated and deoxygenated hemoglobin concentrations inside tissues such as skin, muscle, and the brain. The overall footprint of the device is small enough to be deployed in wearable physio-logging devices. We show that changes in hemoglobin concentration can be recorded from bottlenose dolphins and gray seals with signal quality comparable to that achieved in human recordings. We further discuss functionality, benefits, and limitations of NIRS as a standard tool for animal care and wildlife tracking for the marine mammal research community.Publisher PDFPeer reviewe

    Effect of the presence of amniotic fluid for optical transabdominal fetal monitoring using Monte Carlo simulations

    Get PDF
    About a third of babies are delivered by Cesarean section. There has been an increase in maternal deaths during labor due to complications with subsequent births after a C-section. Therefore, there is a clinical motivation to reduce the C-section rate. Current techniques are, however, inefficient at determining fetal distress leading to a high false positive rate for complications and ultimately a C-section. For the current study, Monte Carlo simulations were used to calculate the amount of signal received on a model of a pregnant mother, as well as, the percent of the signal that comes from the fetal layer. Models with and without a 1 mm amniotic fluid were compared and showed differing trends

    Evaluating feasibility of functional near-infrared spectroscopy in dolphins

    Get PDF
    SIGNIFICANCE: Using functional near-infrared spectroscopy (fNIRS) in bottlenose dolphins (Tursiops truncatus) could help to understand how echolocating animals perceive their environment and how they focus on specific auditory objects, such as fish, in noisy marine settings. AIM: To test the feasibility of near-infrared spectroscopy (NIRS) in medium-sized marine mammals, such as dolphins, we modeled the light propagation with computational tools to determine the wavelengths, optode locations, and separation distances that maximize sensitivity to brain tissue. APPROACH: Using frequency-domain NIRS, we measured the absorption and reduced scattering coefficient of dolphin sculp. We assigned muscle, bone, and brain optical properties from the literature and modeled light propagation in a spatially accurate and biologically relevant model of a dolphin head, using finite-element modeling. We assessed tissue sensitivities for a range of wavelengths (600 to 1700 nm), source-detector distances (50 to 120 mm), and animal sizes (juvenile model 25% smaller than adult). RESULTS: We found that the wavelengths most suitable for imaging the brain fell into two ranges: 700 to 900 nm and 1100 to 1150 nm. The optimal location for brain sensing positioned the center point between source and detector 30 to 50 mm caudal of the blowhole and at an angle 45 deg to 90 deg lateral off the midsagittal plane. Brain tissue sensitivity comparable to human measurements appears achievable only for smaller animals, such as juvenile bottlenose dolphins or smaller species of cetaceans, such as porpoises, or with source-detector separations ≫100  mm in adult dolphins. CONCLUSIONS: Brain measurements in juvenile or subadult dolphins, or smaller dolphin species, may be possible using specialized fNIRS devices that support optode separations of >100  mm. We speculate that many measurement repetitions will be required to overcome hemodynamic signals originating predominantly from the muscle layer above the skull. NIRS measurements of muscle tissue are feasible today with source-detector separations of 50 mm, or even less.Publisher PDFPeer reviewe

    Wearable near-infrared spectroscopy as a physiological monitoring tool for seals under anaesthesia

    Get PDF
    Chemical immobilisation of pinnipeds is a routine procedure in research and veterinary practice. Yet, there are inevitable risks associated with chemical immobilisation, and the physiological response to anaesthetic agents in pinnipeds remains poorly understood. The current study used wearable continuous-wave near-infrared spectroscopy (NIRS) data from 10 trials of prolonged anaesthesia (0.5 to 1.4 h) induced through ketamine and midazolam in five grey seals (Halichoerus grypus) involved in other procedures. The aim of this study was to (1) analyse the effect of each compound on heart rate, arterial oxygen saturation (SpO2), and relative concentration changes in oxygenated [ΔO2Hb] and deoxygenated haemoglobin [ΔHHb] in cerebral tissue and (2) to investigate the use of NIRS as a real-time physiological monitoring tool during chemical immobilisation. Average group responses of ketamine (n = 27) and midazolam (n = 11) administrations were modelled using generalised additive mixed models (GAMM) for each dependent variable. Following ketamine and midazolam administration, [ΔHHb] increased and [ΔO2Hb] remained relatively stable, which was indicative of apnoea. Periods of apnoea were confirmed from respiratory band data, which were simultaneously collected during drugging trials. Given that SpO2 remained at 97% during apnoea, we hypothesized that increasing cerebral [ΔHHb] was a result of venous congestion as opposed to decreased oxygen delivery. Changes in heart rate were limited and appeared to be driven by the individual pharmacological actions of each drug. Future research could include simultaneous measures of metabolic rate, such as the relative change in concentration of cytochrome-c-oxidase, to guide operators in determining when apnoea should be considered prolonged if changes in [ΔHHb] and [ΔO2Hb] occur beyond the limits recorded in this study. Our findings support the use of NIRS as real-time physiological monitoring tool during pinniped chemical immobilisation, which could assist veterinarians and researchers in performing safe anaesthetic procedures

    Optical imaging and spectroscopy for the study of the human brain: status report.

    Get PDF
    This report is the second part of a comprehensive two-part series aimed at reviewing an extensive and diverse toolkit of novel methods to explore brain health and function. While the first report focused on neurophotonic tools mostly applicable to animal studies, here, we highlight optical spectroscopy and imaging methods relevant to noninvasive human brain studies. We outline current state-of-the-art technologies and software advances, explore the most recent impact of these technologies on neuroscience and clinical applications, identify the areas where innovation is needed, and provide an outlook for the future directions

    Depth discrimination in diffuse optical transmission imaging by planar scanning off-axis fibers: initial applications to optical mammography.

    Get PDF
    We present a method for depth discrimination in parallel-plate, transmission mode, diffuse optical imaging. The method is based on scanning a set of detector pairs, where the two detectors in each pair are separated by a distance δDi along direction δ D i within the x-y scanning plane. A given optical inhomogeneity appears shifted by αi δ D i (with 0≤ αi ≤1) in the images collected with the two detection fibers of the i-th pair. Such a spatial shift can be translated into a measurement of the depth z of the inhomogeneity, and the depth measurements based on each detector pair are combined into a specially designed weighted average. This depth assessment is demonstrated on tissue-like phantoms for simple inhomogeneities such as straight rods in single-rod or multiple-rod configurations, and for more complex curved structures which mimic blood vessels in the female breast. In these phantom tests, the method has recovered the depth of single inhomogeneities in the central position of the phantom to within 4 mm of their actual value, and within 7 mm for more superficial inhomogeneities, where the thickness of the phantom was 65 mm. The application of this method to more complex images, such as optical mammograms, requires a robust approach to identify corresponding structures in the images collected with the two detectors of a given pair. To this aim, we propose an approach based on the inner product of the skeleton images collected with the two detectors of each pair, and we present an application of this approach to optical in vivo images of the female breast. This depth discrimination method can enhance the spatial information content of 2D projection images of the breast by assessing the depth of detected structures, and by allowing for 3D localization of breast tumors

    Comparison of static and dynamic cerebral autoregulation under anesthesia influence in a controlled animal model.

    No full text
    The brain's ability to maintain cerebral blood flow approximately constant despite cerebral perfusion pressure changes is known as cerebral autoregulation (CA) and is governed by vasoconstriction and vasodilation. Cerebral perfusion pressure is defined as the pressure gradient between arterial blood pressure and intracranial pressure. Measuring CA is a challenging task and has created a variety of evaluation methods, which are often categorized as static and dynamic CA assessments. Because CA is quantified as the performance of a regulatory system and no physical ground truth can be measured, conflicting results are reported. The conflict further arises from a lack of healthy volunteer data with respect to cerebral perfusion pressure measurements and the variety of diseases in which CA ability is impaired, including stroke, traumatic brain injury and hydrocephalus. To overcome these differences, we present a healthy non-human primate model in which we can control the ability to autoregulate blood flow through the type of anesthesia (isoflurane vs fentanyl). We show how three different assessment methods can be used to measure CA impairment, and how static and dynamic autoregulation compare under challenges in intracranial pressure and blood pressure. We reconstructed Lassen's curve for two groups of anesthesia, where only the fentanyl anesthetized group yielded the canonical shape. Cerebral perfusion pressure allowed for the best distinction between the fentanyl and isoflurane anesthetized groups. The autoregulatory response time to induced oscillations in intracranial pressure and blood pressure, measured as the phase lag between intracranial pressure and blood pressure, was able to determine autoregulatory impairment in agreement with static autoregulation. Static and dynamic CA both show impairment in high dose isoflurane anesthesia, while low isoflurane in combination with fentanyl anesthesia maintains CA, offering a repeatable animal model for CA studies
    • …
    corecore